Over 300 Virginia Auctions End Tomorrow 07/21 - Bid Now
Over 450 Total Lots Up For Auction at Three Locations - CA 07/22, KS 07/24, CA 07/31

stats
DOTmed text ad

Probo Medical | We Buy, Repair, and Sell New and Used Ultrasound Equipment

We provide sales, service, rental, and repair for ultrasound systems, probes, and C-arms. We have the largest inventory in the world. Contact us about our special offers on certified refurbished equipment! Call: 317-759-9210 Email: sales@probomedical.com.

stats
stats
DOTmed text ad

North America's Ultimate Probe Repair Lab & Certified Refurbished OEM Probes in Stock

North America's trusted source for ultrasound probe repair and certified refurbished OEM probes. Free evaluations, 1-year warranty, fast turnaround for GE, Philips, Sonosite, Canon, Toshiba, and more. Call (224) 265-7640 / Sales@Lenard.Healthcare

DOTmed Certified stats
MyLab™A70 from Esaote
MyLab™A70 from Esaote
New Product Showcase
spacer
Por Página

Listados

Service For TEKMAR Stratum Purge & Trap Automated VOC Sample Prep System for Multi-vendor service and repair Gas Chromatograph

Service Contracts - we support and maintain your equipment with our staff of chemists and service engineers Depot Repair - Send us your equipment for repair! Broken equipment? Send it to us for... ver más

July 19  

Service For GE HEALTHCARE GE Voluson E8 System Blue Screen GE Voluson E8 System Blue Screen

Faulty Phenomenon The system repeatedly experienced blue screen errors with "system file missing" messages. While reinstalling the system provided a temporary fix, the problem returned within a... ver más

July 18  
Doris Chou / Volka Medical Tech Co LTD
teléfono: +86 13076761531

Service For GE HEALTHCARE GE Vivid E9 System Boot Failure GE Vivid E9 System Boot Failure

Faulty Phenomenon The GE Vivid E9 ultrasound system failed to start properly. During boot-up, the progress bar showed an error message, then the screen turned black and the system shut down... ver más

July 18  
Doris Chou / Volka Medical Tech Co LTD
teléfono: +86 13076761531

Service For GE HEALTHCARE GE Vivid 7 System Crash GE Vivid 7 System Crash

Faulty Phenomenon GE Vivid 7 system experienced repeated crashes over three weeks: - Initially crashed twice within two weeks - Completely failed to start in third week - Displayed error:... ver más

July 18  
Doris Chou / Volka Medical Tech Co LTD
teléfono: +86 13076761531

Service For GE HEALTHCARE GE LOGIQ Series System Freeze GE LOGIQ Series System Freeze

Faulty Phenomenon System intermittently freezes during morning startup, with these symptoms: - Run/Set buttons flashing in lower right corner - Touchscreen and trackball become unresponsive ... ver más

July 18  
Doris Chou / Volka Medical Tech Co LTD
teléfono: +86 13076761531

Service For ALOKA α10 Ultrasound System - Image Echo Issue ALOKA α10 Ultrasound System - Image Echo Issue

Faulty Phenomenon The ALOKA α10 system showed: - No echo with abdominal probes - Weak echo with superficial probes - Normal echo with cardiac probe Troubleshooting and Solutions ALOKA... ver más

July 18  
Doris Chou / Volka Medical Tech Co LTD
teléfono: +86 13076761531

Service For GE HEALTHCARE GE Vivid 7 System Crash & Communication Failure GE Vivid 7 System Crash & Communication Failure

Faulty Phenomenon The GE Vivid 7 system experienced repeated crashes over three weeks: - Crashed twice within two weeks (temporarily fixed by restarting) - Completely failed to start in the... ver más

July 18  
Doris Chou / Volka Medical Tech Co LTD
teléfono: +86 13076761531

Service For GE HEALTHCARE GE Vivid E9 System Boot Failure GE Vivid E9 System Boot Failure

Faulty Phenomenon The GE Vivid E9 system restarted repeatedly after the BIOS screen and couldn't proceed to the ultrasound application. Troubleshooting and Solutions GE Vivid E9 System Boot... ver más

July 18  
Doris Chou / Volka Medical Tech Co LTD
teléfono: +86 13076761531

Service For PHILIPS MEDICAL Philips IE33 System Crash - Error 200 Philips IE33 System Crash - Error 200

Faulty Phenomenon The Philips IE33 system experienced intermittent crashes showing Error 200, requiring complete power cycling to restore function. Troubleshooting and Solutions Philips IE33... ver más

July 18  
Doris Chou / Volka Medical Tech Co LTD
teléfono: +86 13076761531

Service For PHILIPS MEDICAL Philips CX30 System Freezing Issue Philips CX30 System Freezing Issue

Faulty Phenomenon The system repeatedly froze during use, becoming completely unresponsive. Error messages about a "new keyboard" appeared before crashes. Troubleshooting and Solutions Philips... ver más

July 18  
Doris Chou / Volka Medical Tech Co LTD
teléfono: +86 13076761531

Service For PHILIPS MEDICAL Philips CX30 System Crashes Philips CX30 System Crashes

Faulty Phenomenon The Philips CX30 system started up normally but frequently crashed during operation, showing "new keyboard detected" errors. Troubleshooting and Solutions Philips CX30 System... ver más

July 18  
Doris Chou / Volka Medical Tech Co LTD
teléfono: +86 13076761531

Service For GE HEALTHCARE GE VIVID I system maintainance GE VIVID I system maintainance

Faulty Phenomenon GE VIVID I Ultrasound System Repair Case: Fixing "Probe Not Recognized" Error Troubleshooting and Solutions GE VIVID I Ultrasound System Repair Case: Fixing "Probe Not... ver más

July 18  
Doris Chou / Volka Medical Tech Co LTD
teléfono: +86 13076761531

Service For CONMED System 5000 Flat Rate Repair Service Electrosurgical Unit

This listing offers a flat-rate repair service for your Conmed System 5000 unit. Our comprehensive service goes beyond typical repairs; we diagnose and address circuitry issues and perform a... ver más

July 10  
Terrain Biomedical & Consulting
teléfono: +1 (773) 697-8400

Service For GE HEALTHCARE Logiq E9 Ultrasound System

Full service contracts available Time and materials Parts... ver más

July 17  

Service For VERATHON Glidescope AVL System

Verathon Glidescope AVL system – $3500 baton exchanges vs $5k OEM. Complete systems $9500. We offer FREE shipping and eval prior to repair. 1-3 week average turnaround time. Please email or... ver más

July 15

Asking Price:
$3,500 USD

Patrick Reed / XS BioMedical Solutions
teléfono: +1 (800) 299-5201