Over 1650 Total Lots Up For Auction at Two Locations - PA 07/14, NJ Cleansweep 07/16

stats
DOTmed text ad

North America's Ultimate Probe Repair Lab & Certified Refurbished OEM Probes in Stock

North America's trusted source for ultrasound probe repair and certified refurbished OEM probes. Free evaluations, 1-year warranty, fast turnaround for GE, Philips, Sonosite, Canon, Toshiba, and more. Call (224) 265-7640 / Sales@Lenard.Healthcare

DOTmed Certified stats
stats
DOTmed text ad

Probo Medical | We Buy, Repair, and Sell New and Used Ultrasound Equipment

We provide sales, service, rental, and repair for ultrasound systems, probes, and C-arms. We have the largest inventory in the world. Contact us about our special offers on certified refurbished equipment! Call: 317-759-9210 Email: sales@probomedical.com.

stats
Mako meter by RTI Group
Mako meter by RTI Group
New Product Showcase
spacer
Por Página

Listados

Service For GE HEALTHCARE Repairing ultrasound GE Voluson E8 BT13. Repairing ultrasound GE Voluson E8 BT13.

Faulty Phenomenon Malfunction: Upon loading the device, the error "Mixed RSR configuration found" was fixed, due to which the system did not start. Troubleshooting and Solutions Malfunction: Upon... ver más

June 30  
Doris Chou / Volka Medical Tech Co LTD
teléfono: +86 13076761531

Service For GE HEALTHCARE Repair GE Voluson E6 BT19. Repair GE Voluson E6 BT19.

Faulty Phenomenon Description of the problem: during the examination, flickering and interference appear on all sensors. The problem was progressive in nature, that is, with each time the... ver más

June 30  
Doris Chou / Volka Medical Tech Co LTD
teléfono: +86 13076761531

Service For GE HEALTHCARE Repair GE Voluson E10 BT21. Repair GE Voluson E10 BT21.

Faulty Phenomenon Description of the problem: during the examination, all sensors display flickering and interference. The problem was progressive in nature, meaning that with each examination, the... ver más

June 30  
Doris Chou / Volka Medical Tech Co LTD
teléfono: +86 13076761531

Service For GE HEALTHCARE Repair GE Voluson S8 BT16. Repair GE Voluson S8 BT16.

Faulty Phenomenon Description of the problem: when connecting both sensors of the RAB6-RS, an error appears in the Motor Control Unit. Troubleshooting and Solutions Description of the problem:... ver más

June 30  
Doris Chou / Volka Medical Tech Co LTD
teléfono: +86 13076761531

Service For GE HEALTHCARE Repairing the ultrasound device GE ML6-15-D. Repairing the ultrasound device GE ML6-15-D.

Faulty Phenomenon Replacement of the acoustic lens (photo before replacement, inside the post - after... ver más

June 30  
Doris Chou / Volka Medical Tech Co LTD
teléfono: +86 13076761531

Service For GE HEALTHCARE Repairing the ultrasound device GE RM6C. Repairing the ultrasound device GE RM6C.

Faulty Phenomenon Restoration of the sealing of the piston (problem: leakage of oil was detected under the piston). Troubleshooting and Solutions Restoration of the bellows seal (problem: an oil... ver más

June 30  
Doris Chou / Volka Medical Tech Co LTD
teléfono: +86 13076761531

Service For GE HEALTHCARE Repairing GE Voluson E10 equipment. Repairing GE Voluson E10 equipment.

Faulty Phenomenon Malfunction: During the examination, artifacts appear in the form of bright spots, morgania, etc. With each examination, the artifacts increase. Solution: The malfunction was... ver más

June 30  
Doris Chou / Volka Medical Tech Co LTD
teléfono: +86 13076761531

Service For GE HEALTHCARE Repair equipment GE Logiq E9 R6. Repair equipment GE Logiq E9 R6.

Faulty Phenomenon Malfunction: when turning on, an error appears, associated with overheating of the device solution: the TO of the device was performed, and the MRX192 board was also repaired. ... ver más

June 21  

Service For GE HEALTHCARE Repair ultrasound GE Logiq S8 R2. Repair ultrasound GE Logiq S8 R2.

Faulty Phenomenon Malfunction: Based on the results of the service testing, the board BF192 (5357234-20) is faulty. The malfunctioning channel has been identified as the cause of the device's... ver más

June 30  
Doris Chou / Volka Medical Tech Co LTD
teléfono: +86 13076761531

Service For GE HEALTHCARE Repair GE Logiq E9 R6 (XDClear 2.0). Repair GE Logiq E9 R6 (XDClear 2.0).

Faulty Phenomenon Malfunction: when turning on, a net image is displayed on the screen instead of the "dynamic circles" image, and non-existent sensors are also reflected. Replaced faulty... ver más

June 30  
Doris Chou / Volka Medical Tech Co LTD
teléfono: +86 13076761531

Service For GE HEALTHCARE Repair GE Voluson E8 (BT12). Repair GE Voluson E8 (BT12).

Faulty Phenomenon A stripe appeared on the display of the RST board (PN: KTZ196358, KTZ280122). RST - impulse transmission board, 16 pieces are installed in the device (1 faulty). Sent the board... ver más

June 30  
Doris Chou / Volka Medical Tech Co LTD
teléfono: +86 13076761531

Service For GE HEALTHCARE Repair GE Logiq E10 (version R3). Repair GE Logiq E10 (version R3).

Faulty Phenomenon GE Logiq E10: A malfunction was detected in the TX board, an element that controls the switching on/off of high voltage for supply to the acoustic module has failed. The device is... ver más

June 30  
Doris Chou / Volka Medical Tech Co LTD
teléfono: +86 13076761531

Service For GE HEALTHCARE Repair device GE Philips Epiq 5. Repair device GE Philips Epiq 5.

Faulty Phenomenon Malfunction: error 607 indicates a malfunction in the data base solution: after restarting the PO device, it worked. Troubleshooting and Solutions Malfunction: error 607... ver más

June 21  

Service For GE HEALTHCARE GE Voluson E8 BT21 device repair. GE Voluson E8 BT21 device repair.

Faulty Phenomenon Malfunction: During the examination, echo-imaging disappears and everything turns into white color. Solution: repair RFM323 plate. Troubleshooting and Solutions Malfunction:... ver más

June 21  

Service For GE HEALTHCARE Repair device GE Voluson E10 B21. Repair device GE Voluson E10 B21.

Faulty Phenomenon Malfunction: during operation, a blue screen appears on the device. Sometimes the device does not turn on and the power button flashes yellow. Solution: repair the power supply... ver más

June 21