GS-270 Rotating Anode X-Ray Tube
Scanner Type - Sytec 1600/1800
Housing Type - B-150H
OEM - GE

Please contact us for more information

Varex Imaging and GS-270 are trademarks of Varex Imaging. All other trademarks are trademarks of the respective OEM.



The GS-270 is a 4.0” (102 mm) 135 kV, 445 kJ (600 kHU) maximum anode heat content, rotating anode insert. This insert is specifically designed for CT Scanners. The insert features a 7° tungsten-rhenium facing on molybdenum with a graphite backed target and is available with the following nominal focal spot:
0.6
IEC 60336

Loading Factor for slit focal:
120 kV, 25 mA

Maximum Anode Cooling Rate:
2,000 W (2,800 HU/sec)

Maximum continuous anode heat
dissipation:
1,500 W (2,100 HU/sec)

Nominal Anode Input Power:
15 kW IEC 60613

Reference Axis:
Perpendicular to port face.

This insert is intended for use in a Varex Imaging B-150H housing.

Maximum Peak Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135 kV
Anode to Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 kV
Cathode to Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 kV
Maximum X-ray Tube Assembly Heat Content . . . . . . . . . . . 1,111 kJ (1.5 MHU)
Maximum Continuous Heat Dissipation (max. housing temperature 78°C)
(Includes stator heat) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,800 Watts (2,520 HU/sec)
Focal Point Position (Central Ray) Within 1mm
(X, Y Direction from the center of radiation port.)
X-Ray Tube Assembly
Permanent filtration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0 mm Al IEC 60522
Loading Factors for Leakage Radiation . . . . . . . . . . . . . . . . . . . . . . . 135 kV, 15 mA
Federal Standard High Voltage Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Ambient Air Temperature Limits for Operation . . . . . . . . . . . . . . . . . . . 5°C to 35°C
Temperature Limits for Storage and Transport . . . . . . . . . . . . . . . . -20°C to +70°C
Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10% - 90%
Weight: Housing & Tube . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33.5 kg (74 lbs)
IEC Classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Class 1
Safety Devices - Thermal Switch
Normally Closed Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . Opening at 85°C ±3.9°C
Filament Frequency Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 HZ - 25 kHZ
Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DC