Click here for more product information

The GS-2176 is a 5.0” (127 mm) 140 kV, 1.43 MJ (2.0 MHU) maximum anode heat content, rotating anode insert. This insert is specifically designed for CT Scanners. The insert features a 7° rhenium tungsten facing on molydenum with a graphite backed target and is available with the following nominal focal spots:
1.0 x 0.6
IEC 60336
Loading Factor for slit focal:
120 kV, 100 mA
Maximum Anode Cooling Rate:
4,000 W (5,600 HU/sec)
Maximum continuous anode
heat dissipation:
3,800 W (5,320 HU/sec)
Nominal Anode Input Power:
Large - 42 kW IEC 60613
Reference Axis:
Perpendicular to port face.
This insert is intended for use in a
MX135MV housings.
Maximum Peak Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 kV
Anode to Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 kV
Cathode to Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 kV
Maximum X-ray Tube Assembly Heat Content . . . . . . . . . . 1.43 MJ ( 2.0 MHU)
Maximum Continuous Heat Dissipation (max. housing temperature 78°C)
(Includes stator heat) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.5 kW (6.3 kHU/sec)
Focal Point Position (Central Ray) Within 1mm
(X, Y Direction from the center of radiation port.)
X-Ray Tube Assembly
Permanent filtration . . . . . . . . . . . . . . . . . . . . . . . . 1.2 mm Al @ 140 kV, IEC 60522
Loading Factors for Leakage Radiation . . . . . . . . . . . . . . . . . . . . . . . 140 kV, 29 mA
Temperature Limits for Storage and Transport . . . . . . . . . . . . . . . . -20°C to + 80°C
Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10% - 95%
Weight: Tube Assembly (Tube & Housing) .. . . . . . . . . . . . . . . . . 53.1 kg (118 lbs)
IEC Classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Class 1
Safety Devices - Thermal Switch
Normally Closed Contact . . . . . . . . . . . . . . . . . . . . . . . . . . Opening at 68°C to 79°C
Safety Devices: Pressure Switch
Normally Closed Contact . . . . . . . . . . . . . . . . . . . . . . . . . . Opens at 5PSIG ±3 PSIG
Filament Frequency Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 HZ - 25 kHZ
Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DC