Used OEC Uroview 2800 Urology Suite Un venta del la - DOTmed Listado #2455102:

Huge Two-Day Clean Sweep Auction July 24-25th. Click Here to Bid!

advertisement
OEC Uroview 2800 Urology Suite for sale OEC Uroview 2800 Urology Suite for sale OEC Uroview 2800 Urology Suite for sale OEC Uroview 2800 Urology Suite for sale OEC Uroview 2800 Urology Suite for sale
OEC Uroview 2800 Urology Suite for sale OEC Uroview 2800 Urology Suite for sale OEC Uroview 2800 Urology Suite for sale OEC Uroview 2800 Urology Suite for sale OEC Uroview 2800 Urology Suite for sale

A la venta OEC Uroview 2800 Urology Suite

  • Asking Price :€4,000.00 EUR
  • Condition : Used - Good
  • Quantity : 1
  • In Stock : Yes
  • Date : July 10, 2019

Item Description

Seller assumes all responsibility for this listing.

Listing: #2455102

  • Condition: Used - Good
  • Brand: OEC
  • Type: Urology Suite
  • Model: Uroview 2800
  • Year of Manufacture: 2003
Article: 17438
Pre-owned GE OEC Uroview 2800 X-ray unit designed for fluoroscopic real-time imaging and for making x-ray examinations of patients during examinations as well as surgical and interventional procedures.
Possible clinical applications include urological and endoscopic procedures, but application possibilities are not limited to these two areas. According to medical judgement the system can also be used for other X-ray applications

The Uroview System is consisting of the following components:
-Workstation
-Generator
-Table
-X-ray head
-Image intensifier
-Pillar

Tube Specification:
-Insert type: Varian A286
-Housing type: Varian B130
-Maximum rated power of x-ray tube (anode to cathode): 150 kVp max.
-Type: Rotating anode
-Kilowatt rated power: 0,3 mm – 8,5 kW; 1,2 mm – 96 kW
-Focal spot: Dual, 3 mm and 1,2 mm
-Eyepiece angle: 12°
-Eyepiece diameter: 102 mm
-Extent: 42,5 cm x 42,5 cm; 112,5 cm at receptor
-Total filtration: 2,8 mm Aluminum-filter equivalent; added to beam (in collimator): 2,0 mm; Inherent (tube only): 0,8 mm
-Inherent filtration: 0,8 mm AL +/- 0,5 mm @ 75 kVp
-Cooling rate: 18 kHU/Min
-Housing thermal capacity: 2000000 HU minimal
-Technology factors loss: 120 kVp and 5,0 mA (rated capacity after 1 hour)

Technical Data:
Nominal kVp @ max. mA
-Film mode: 125 kVp @ 600 mAs
-General fluoroscopy: 125 kVp @ 10 mA
-HLF-fluoroscopy: 125 kVp @ 20 mA
-Pulsed fluoroscopy: 125 kVp @ 40 mA

Nominal mA @max. kVp
-Film mode: 600 mAs @ 125 kVp
-General fluoroscopy: 10 mA @ 125 kVp
-HLF-fluoroscopy: 20 mA @ 125 kVp
-Pulsed fluoroscopy: 40 mA @ 125 kVp

Maximum Output
-Film mode: 40kW @ 125 kVp = 320 mA; 65kW @ 125 kVp = 520 mA; 80kW @ 125 kVp = 640 mA
-Pulsed fluoroscopy: 5,0 kW @ 125 kVp, 40 mA

Nominal Output
-Film mode: 40kW @ 125 kVp = 320 mA; 65kW @ 125 kVp = 520 mA; 80kW @ 125 kVp = 640 mA

Minimum mAs Setting
-Film mode: 15,0 mAs (independent of kVp)

YOM:October 2003

The unit is dismanteled and ready for shipment. Packing list availabe.
Seller Information
Scopet Medical Solution Limited
Shop with confidence
[x]
Chat with the Owner

We're Offline

Send message to seller