Item Description

Seller assumes all responsibility for this listing..

Listing: #2181455

  • Condition: Used - Excellent
  • Brand: CAREFUSION
  • Type: Pump IV Infusion
  • Model: 8100
  • MPN: 8100
  • Depth: 4 inches
  • Height: 10 inches
  • Width: 6 inches
  • Warranty: 90 Days

The CareFusion Alaris Model 8100 Pump Module comes with your choice of software. Software version 9.17 also works with older versions of the software and version 9.33 is only compatible with that current version of the software. This top-of-the-line Pump Module is intended for facilities that utilize infusion pumps for the delivery of fluids, medications, blood, and blood products using continuous or intermittent delivery through clinically acceptable routes of administration; such as, intravenous (IV), intra-arterial (IA), subcutaneous, epidural, enteral, or irrigation of fluid spaces.

Warranty: 90 Days.

It is designed for use on adults, pediatrics, and neonates.

CareFusion Alaris Model 8100 Pump Module Features
  • Auto-restart.
  • Bolus dose.
  • Channel labels.
  • Concentration limits.
  • Delay options.
  • Drug calculation.
  • Dynamic pressure display.
  • Free flow protection.
  • Guardrails drug library.
  • Guardrails limit.
  • KVO rate adjust.
  • Multi-dose mode.
  • Occlusion pressure.
  • Rapid Bolus.
  • Restore.
  • Secondary infusions.
  • Volume/Duration.
  • High contrast, illuminated keypad provides visibility in low-light environments.
  • Squared, raised-edge keys provide large touchpoints.
CareFusion Alaris Model 8100 Pump Module Specifications
  • Dimensions: 5.5" (D) x 3.3" (W) x 8.9" (H).
  • Operating Temperature: 41 to 104 °F (5 to 40 °C).
  • Bolus Volume following Occlusion, Maximum:Pressure Limit (mmHg)Pressure Limit (mmHg)Rate5052525≤ 0.3 mL≤ 0.6 mL
  • Accumulated Air Window:Single Bolus SettingVolume Window (mL)% Air that Causes Alarm502.810%758.020%2508.030%50012.030%
  • Rate Accuracy: The Medley Medication Safety System is ± 5% at rates between 1 and 999 mL/h, and ± 5.5% at rates less than 1 mL/h, 95% of the time of 95% confidence, under conditions listed below:
    • Infusion Rate Range: 0.1 to 999 mL/h.
    • Ambient Temperature: 68 ± 4 °F (20 ± 2 °C).
    • Source Container Height: 20" above top of Pump module.
    • Test Solution: Distilled water.
    • Distal Back Pressure: 0 mmHg (0 kPa).
    • Needle: 18 Gauge.
    • Administration Set Module: 2210.
Software VersionsCareFusion Alaris Model 8100 Pump Module Software Versions
  • #8100: 9.17 Software (works with older software verisions as well).