Item Description

Seller assumes all responsibility for this listing..

Listing: #4793768

  • Condition: Used - Good
  • Brand: PHILIPS
  • Type: Other
  • Model: Intellivue
  • MPN: MX40-1B4
  • Depth: 12 inches
  • Height: 6 inches
  • Width: 10 inches
MPN: MX40-1B4, MX40, 8653050, S02

*Listing is for ONE unit (monitor only). Multiple available.*

*LOT of ONE*

Light use from a DoD Hospital. Units were replacements for new certified, in use, units (couldn't wait for recertifications).

Item is not under any recall.

Philips IntelliVue MX40 Patient Wearable Monitor

MX40-1B4 (Possible software difference with -1C4, but cases do not have pull ridges on battery cover. Some -1C4's do)

8653050/865350V

1.4GHz

S02; ECG + SpO2

Options include:

S02, FAST SpO2 Enabled

C01, Enhanced Arrhythmia

C03, Vitals Trend

J46, Short Range Radio

M02, Impedance Respiration

See Philips for Service Manual:

documents.philips.com/doclib/enc/fetch/2000/4504/577242/577243/577247/582636/582882/MX40_B.0_Service_Guide.pdf

Reminder:

Configuration Mode is password protected. The default mfr password to enter is "71034".

Service Mode is password protected. The default mfr password to enter is "1345".

Demo Mode is password protected. The default mfr password to enter is "14432".




Compatibility:

The MX40 (865350/865351) is compatible for use with IntelliVue Information Center Release N and IntelliVue Information Center iX Release A.00. Limited compatibility is offered when used with IntelliVue Information Center Release L or M. See the "Operating with Release L or M" chapter for more information.

The MX40 is compatible for use with IntelliVue Patient Monitors Release G or later when wirelessly connected (IIC Release N).

The MX40 is compatible for use with IntelliVue Patient Monitors Release J or later when wirelessly connected (IIC iX Release A.00).

The MX40 is compatible for use with IntelliVue Cableless Measurements Release A.1.

The MX40 (865350/865351) is compatible for use with Access Point Controller 862147, Release B.00.19 and Access Point Controller 865346, Release C.00.04.

The MX40 Patient Cable is compatible for use with IntelliVue Patient Monitor platforms MP2/X2, MP5/MP5T/MP5SC, MP20/30 with MMS or X2, MP40/50 with MMS or X2, MP60/70 with MMS or X2, MP80/90 with MMS or X2, and MX800/700/600 with MMS or X2.



From manufacturer:Philips IntelliVue MX40 Features

The Philips IntelliVue MX40 is a wearable patient monitor. Its designed to support ambulatory patients for continuous ECG and optionally, SpO2, and impedance respiration. The short-range radio options allow connection to the IntelliVue Cableless Measurements or an IntelliVue patient monitor for additional parameters. The display on the IntelliVue MX40 provides immediate access to patient information at the point of care. The 6-lead and two V-leads can be used for diagnosing multiple cardiac abnormalities, including wide-QRS complex tachycardias and acute myocardial ischemia/infarction.

Easy for clinicians to use and comfortable for patients to wear.
2.8 color, touchscreen display.
Smart, multi-measurement cable system available for use with reusable and single-patient-use supplies.
FAST SpO2 (Continuous, automatic, or manual measurement)
Standard, EASI, or Hexad ECG lead system selection.
Communication with IntelliVue Patient Monitors and Cableless Measurements via a short-range radio connection.
Powered by three AA batteries or rechargeable lithium-ion battery pack.
Philips IntelliVue MX40 SpecificationsDimensionsHeight: 4.99 (12.7 cm)
Width: 2.75 (7 cm)
Depth: 1.24 (3.2 cm)
Weight (Without Batteries): 8.5 oz (240 g)
BatteryLithium-ion battery pack or 3 AA batteries
Charge Time: 6.5 Hours (Lithium-ion battery)
DisplayType: 2.8 QVGA Color LCD
View Area: 1.7 x 2.3 (4.3 cm x 5.8cm)
Resolution: 240 x 320
Backlit: White LED
EnvironmentalTemperatureOperating: 23 to 99F ( 0 to 37C)
Storage: -22 to 122F (-30 to 35C) without batteries

HumidityOperating: < 95% RH at 98.6F (37C)
Storage: < 90% RH at 122F (50C)

AltitudeOperating & Non-operating: 9,842 ft (3,000 m)
Barometric Pressure: 537 mmHg (72 kPa)

ECGLead Wires: 3, 5 or 6-wire patient cable compatible with IntelliVue Patient Monitor, AAMI/IEC color codes
Resolution: 5V
ECG Input: Differential, defibrillator protected against 360 joules discharge into a 100 ohm load
Input Impedance: > 5 meohms (@ 10 Hz
Input Dynamic Range: +/- 9 mV
DC Offset Range: +/- 320 mV
CMRR: 90 dB @ 50, 60 Hz
FAST SpO2Lead Wires: 3, 5 or 6-wire patient cable compatible with IntelliVue Patient Monitor, AAMI/IEC color codes
Resolution: 5V
ECG Input: Differential, defibrillator protected against 360 joules discharge into a 100 ohm load
Input Impedance: > 5 meohms (@ 10 Hz
Input Dynamic Range: +/- 9 mV
DC Offset Range: +/- 320 mV
CMRR: 90 dB @ 50, 60 Hz




No further testing could be conducted however; there are no visible defects that would impede normal function.

Required Medical Disclaimer:



By purchasing, buyer is stating they are not prohibited from purchase, ownership, or possession of item. Buyer attests they are a physician, licensed healthcare practitioner, or any other practitioner licensed by the law of the State in which the practitioner practices to use or order the use of the device.

"The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not buy this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item."

All items are sold new or used, as-is unless stated otherwise. We do not offer or imply any guarantees or warranties on any equipment sold. It is the responsibility of the buyer to thoroughly inspect by qualified technicians before putting equipment in service. We accept no liability for equipment once it has left our warehouse.

Please note most of the medical equipment pieces need some maintenance and recertification. It is normal and legal requirement. We strongly recommend that you get proper certification prior to use and get the unit completely checked out.

Rubber tubing, seals and such items often need to be replaced on a routinely basis for preventive maintenance on a lot of different types of equipment. It is recommended that they be replaced as per need basis.

Item has been cleaned and handled in accordance with the manufacturer's instructions.



New Orleans, LA

Return Policy

3 Day Return Policy. Customer must pay the return shipping costs when returning a product. Items are sold as-is with no returns or refunds available unless explicitly stated.
Seller Information
Dalma Corp
(1)
Shop with confidence
Citi Capital Groupspacer